- 42-50_Steinbrecht_354_9-1.pdf
-
Paper ID354
-
Paper statusPublished
Poor landfill gases cannot be used to drive gas engines or be burnt in gas flares. This follows
why the combustion flame front velocity for poor gases becomes very low. From this moment
the non-flammable poor landfill gases are polluting the environment. An energetical utilisation
of very poor landfill gases is of ecological interest and is also an important contribution for
climate protection. A feasible solution must be found.
In our University lab we are using a Fluidised Bubbling Bed Combustion (SFBC) plant with
200 kW completed by heat exchangers for pre-heating the combustion air as well the
combustion gas. In the past this SFBC-principle had successfully been applied to a thermal
utilization of very different wastes. Using this principle we are able to recover the energy
content of very poor landfill gases down to a concentration below the lower explosion limit.
The fluidised red hot inertia bed material at a temperature of 850°C is an excellent ignition
source to run the process at constant parameters within legal limits. Therefore we have very
low pollutant emission levels.
Using a developed mathematical SFBC-model we theoretically investigated the lowest
possibly methane concentration limits under given pre-conditions as well as fluidised bed
temperature level, fluidisation air and fuel gas temperatures, necessary oxygen concentration
level. Following to these model investigations we realized their experi-mental verification in
our 200 kW lab SFBC testing plant in a wide-spread plant load range. These lab tests had
very successful results. The possible SFBC operation conditions have been estimated.
Based on these results we engineered by the help of industrial partners a real SFBC plant
installed on a closed landfill in Mecklenburg – Western Pomerania, 65 km far from our
University lab. Using these plant we dispose there real very poor landfill gas. The landfill gas
is poor enough to avoid a further operation of a common gas flare. The automatically
operated SFBC process is running at 850 °C without any technical interruptions since one
year. At the moment the maintenance rate is 3 weeks. The plant is supervised by data remote
control. The contribution will compare the lab test results with the results of the real existing
plant.
If the poor landfill gas flow is strong enough the SFBC produces enough energy e.g. to drive a
steam cycle or a gas turbine externally fired by the SFBC that generates electrical power. In
this case the necessary power equipment has to be added to the SFBC plant.